      HZQ5-40/63A (PC) Dual Power Automatic Transfer Switch

      ŇťĄ˘applicationŁş

      This kind of transfer switchŁŹapplied in 50/60hz AC and rated voltage 660v,  is mainly used in 
      the occasions required uninterrupted power supply like building, 
      posts and telecommunications, mine industry, shipping and military
       industry. Under the necessary trend of urban power service increasing, 
      it can meet the higher requirements of the reliable power service. This 
      product has many features like reliable performance, small volume and 
      simple operating etc.

      standardŁşGB/T14048.1ĄŞ2006GB/T14048.11-2008

      śţĄ˘description:


      NotesŁş

      Number of PolesŁ¨˜O”ľŁŠ

      Rated Operational currentŁ¨î~ś¨š¤×÷ëŠÁ÷ŁŠ

      Design OrderŁ¨ÔOӋĐň̖ŁŠ

      Dual Power Transfer SwitchŁ¨ëpëŠÔ´é_ęPŁŠ

      Enterprise CodeŁ¨Ćó˜I´ú̖ŁŠ

      ČýĄ˘Main Technical Index:


      rated operational currentŁ¨AŁŠ

      40

      63

      80

      100

      125

      160

      200

      250

      400

      630

      given heating currentŁ¨AŁŠ

      40

      63

      80

      100

      125

      160

      200

      250

      400

      630

      rated insulation voltage

                               660

      rated working voltage

                  380                660

      Rated short time withstand currentŁ¨KAŁŠ

      5

      10       15

      Transferring TimeŁ¨SŁŠ

      ĄÜ0.1

      Mechanical durability

                8000

      6000  4000

      Electrical durability

                4000

      3000  2000

      Distance of electric arcingŁ¨mmŁŠ

                 80

              100

      Auxiliary contact capacity

      5A  AC250V;0.5A  DC125V


      ËÄnormal working condition:

      1: Air TemperatureŁş

          (1)Ą˘Maximum temperature +40Ąć; Average temperature  within 24Hrs should not be
       beyond +40Ąć

          (2)Ą˘Minimum temperature-5ĄćŁť

          (3)Ą˘Average temperature within 24 Hrs should not be beyond  +35Ąć

      NotesŁş

      The customer should consult the manufacturer when the top limit of air temperature
       is over +40Ąć and the lower limit of the air temperature is below -10Ąć or -25Ąć.

      2. Ambient temperature: 
         -5ĄÍ - +40ĄÍ; the average value within 24h shall not exceed +35ĄÍRelative humidity at +40
      ĄÍ shall not exceed 50%.  Higher humidity is permissible at lower temperature condition. 
         When the highest monthly average relative humidity is 90% in     the humiddest month,
       the lowest monthly average temperature 
         of this month is +25ĄÍAnd the influence of dew on product  surface due to 
      temperature changes should be taken into 
      consideration.

      3. Altitude of installation place shall not exceed 2000m. 

      4. Pollution grade: grade iii. 

      5. Installation instruction: vertically installations and the vertical     angle shouldnĄŻt 
      exceed 
      22.5.

      Î奢features:

      1. Excitation Control System; DC Pulse Operation; fast switching; lack of coil heating; 
      noiseless; conserving energy.

      2. Manual manipulation and power operator are both available.

      3. Reliable interlock makes sure that the host and the backup power cannot be electrified 
      at the same time.

      4. The adoption of large contact with superior performance makes conductive part steady 
      and reliable.

      5. Strong Arcing ability is subject load.

      6. In accord with the isolator of the qualified rate.  

      ÁůĄ˘operating principle

       When the side voltage relay of main power changes, the side voltage relay of standby 
      power works and switch on its
       time relay, then turns on the middle relay to supply power for its rectifier bridge after 
      a certain of delay, and drives control loop electrical wires, thus the switch acts, the loop
       of main power is disconnected. When the main power turns to normal, its voltage relay
       works turns on the middle relay to supply power for its rectifier bridge after a certain of 
      delay, and drives control loop electrical wires, thus the switch acts, then the standby 
      power is cut and the main power supply restores.


      Ćß
      Ą˘construction of switch

      This series of HZQ5-40/630 automatic transfer switches are consisted of auxiliary contact and main contact
       combined through the mechanical drive. Under the exact and rational design, the 
      electrical equipment and the machine link together at the same time to make sure that 
      the main power and the standby power wonĄŻt be turned on simultaneously. The main 
      contact is made of Silver-tungsten Alloy and Silver-Tungsten Carbide which have strong arc-resistance, so their lifetime can be prolonged. WhatĄŻs more,
       arcing ability is strong 
      and it can be transferred live and can be also transferred by
       hand through operating 
      handle 2. It adopts electromagnetic driving and DC Pulse system so that it can play an 
      important role in reducing the ageing of coins and saving electric energy. The electrical 
      clearance and creepage distance meets the standards with the function of insulation.
       A1,A2 and B1,B2 are two groups of control powerĄŻs connection ports, and A3,B3 are 
      indicative terminals of two power sourcesĄŻ close-break and provide users with two groups of auxiliary contacts(A4,A5,B4,B5) for other utilities.