      HZQ53-10/400A Dual power supply



      һHZQ53 three-step automatic transfer switch (20-5000) A

      1.Main circuit contact beside Power A

      2.on-off indicator of power

      3.option button

      4.trip button

      5.operating square shaft for manual switchover

      6.nameplate

      7.operating power terminal

      8.input circuit

      9.main circuit terminals beside the load

      10.main circuit terminals beside power B

      11.automatic switch

      12.Arc Extinguish Chamber


      HZQ52 three-step automatic transfer switch (20-5000) A
      1.Main circuit contact beside Power A

      2.on-off indicator of power

      3.operating square shaft for manual switchover

      4.nameplate

      5.operating power terminal

      6.input circuit

      7.main circuit terminals beside the load

      8.main circuit terminals beside power B

      9. Arc Extinguish Chamber

      10.automatic switch

      Features of ATS switch
      Reliable mechanical interlock: The unique eccentric selective structure makes 
      sure one power supply to work and there is any possibility of two power sources
       connecting the load at the same time.

      Excellent arc extinction: all kinds of abnormal arc can be extinguished safely, and
       the electric arc lasts for short time with less wear of the contact.

      Multiple-piece main arcing contact: increasing the contact terminals area of surfa
      ce in contact and contact pressure. The superheat and welding wont happen; the 
      life of contact can be prolonged.

      Rapid switchover: it can switch rapidly between main power and standby power and 
      the switching-time delay of ATS equipped with controller can be set by users.

      Simple structure and small size: stable running, low breakdown rate, convenient 
      installation, usage and maintenance. Slow operation by rotating the handle while
       maintaining in order to check and eliminate malfunction.

      HZQ5 ATS belongs to PC type. Its cubage is smaller than that of CB type, but its 
      ampere rating is more than that of PC type.

      Neutral points position: HZQ53 three-step switch can switch over in switch-on 
      regime and stay momently in the neutral point so that it is convenient for users
       to overhaul the load circuit(residence time shouldnt exceed several minutes.) 
      HZQ52 two-step type couldnt stay in the neutral point.

      Multifunctional controller: Liquid crystal display and digital dynamic supervisory 
      control display supply voltage and current, and control the transfer switch to finish 
      switchover as required among main power, standby power and neutral point under 
      the circumstance of over-voltage, over low voltage,
       loss-of-voltage, and non-full-phase.


      product model and meaning
      1The model and meaning of products are as follows:



      1
      HZQ52 is two-step automatic transfer switch. When receiving the change-over 
      signal, the switch wont stop in the middle splitting point and transfer rapidly from 
      one power to another power and its 
      ampere rating is only 20A-500A.

      HZQ53 is three-step automatic transfer switch. It can transfer instantly (or after a 
      predetermined time delay) from one power to anther power after receiving the 
      change-over signal. It can also transfer to the middle splitting point disconnected 
      with other power supplies. Its 
      ampere rating is 20A-5000A.

      2HZQ5 series of switches is PC type.

      3Other electric switches of other standards belong to special supply such as rated 
      operational current is 660v/690v, DC is 125v/250v; control voltage is 380v/400v/100v
      270v; DC is 125v/250v and so on. Users 

      4should specify when ordering. 

      5The switches below 500A should be generally connected in front and the switches 
      above 630A should be connected at back. The others belongs be special supply.


      Parameters of HZQ53 three-step transfer switch.


      The parameters of HZQ52 two-step transfer switches.

      Notes: when the DC works, its structure of loop is almost as same as that of AC, and only a small part is different. Please operate as t
      he orders of AC operations.

      The weight in the chart is for reference only.

      Pole N contacts capacity of these products with 4000A and 5000A is relatively 2000A,2500A.

      Values of rated short time withstand current, operational current, and tipping current are for reference only.


      Normal working condition and installation condition

      (1) When the DC works, its structure of loop is almost as same as that of DC, and only a small part is different. Please 
      operate as the orders 
      of DC operations.

      (2)The outlines and sizes of these three different currents---80A/100A/125A are same as that of HZQ53 three-step transfer 
      switches in the same standard.

         The outlines and sizes of these four different currents---160A/200A/225A /250A are same as that of HZQ53 three-step transfer
       switches in the same standard.

         The outlines and sizes of these three different currents---350A/400A/500A are same as that of the HZQ53 three-step transfer 
      switches in the same standard.

      (1).Ambient temperature: -5 - +40; the average value within 24h shall not exceed +35. (it can be extended not higher than +55 
      and not lower than -25 according to users orders)

      (2). Altitude of installation place shall not exceed 2000m.

      (3). Atmospheric Condition: Relative humidity at +40 shall not exceed 50%. Higher humidity is permissible at lower temperature condition. 
      When the highest monthly average relative humidity is 90% in the humiddest month, the lowest monthly average temperature of this month is +25
      .
       
      And the influence of dew on product surface due to temperature changes should be taken into consideration.

      (4). Pollution grade: complying with required grade iii of GB/t14048.1.

      (5).Installation type: electrical switch installation should accord with required grade iii of GB/14048.1.

         Transfer controllers installation should accord with required grade ii of GB/14048.1

      (6) Installation condition: electrical switches and transfer controller can be installed vertically or horizontally in specified control cabinet and distributor cabinet.

      (7) Protection grade: the shell protection of electric switches accord with the grade 20 of GB4208 IP

         The shell protection of transfer controller accords with the grade 30 of GB4208.

      (8) Using sorts:

      main power circuit

      AC-33B
      occasional operation

      motor load or including motorresistive load mixed load with the load of 30% incandescent lamp

      auxiliary circuit and transfer control circuit

      AC-15
      DC-13

      control AC electromagnet load exceeds 75Vcontrol DC electromagnet load 


      (9)control circuit:

      Rated voltage of control circuit is 220V/250V/50HZ. The voltage of control circuit should accord with the working voltage of transfer controller. Its working
       range: 85% UcQUsQ110%Uc.

      The transfer controller will give conversion instructions when the following happens:

      A disconnection of any phase power or loss of voltage.

      B low voltage: voltage from 180V-230v can be set in a random manner

      C over voltage: voltage from 220V-250v can be set in a random manner

      When delivered, the rated working current is 220V, and its transfer voltage is low voltage 180V and over voltage is 250V 

      (10)auxiliary circuit:

      The auxiliary contact of auxiliary circuit, whose structure is separable, is 4 NO and 4 NC.The rated value of the auxiliary is shown in table 5

      Ith A

      rated insulation voltage V

      rated working current

      10

      400

      AC400

      DC200

      3

      0.2

      abnormal disconnection of auxiliary breaking capacity is shown in table 6

      Using sorts

      connection

      breaking

      operation frequency and numbers of cycling

      1/le

      U/ue

      Cos and t0.95

      1/le

      U/ue

      Cos and t0.95

      numbers of cycling

      operation frequency 

      electrical running time S

      AC-15

      10

      1.1

      0.3

      10

      1.1

      0.3

      10

      2

       0.05

      DC-13

      1.1

      1.1

      6pe

      1.1

      1.1

      6pe

      notesthe upper limit T0.956PeQ300Ms.the electrical running time of DC13 is T0.95 at least when T0.95 R 0.05S.

      Coordination of auxiliary contact and SCPD.

      Series connection of auxiliary contact and fuse in inductive testing circuit whose rated working current is 1.1 times and power factor is between 0.5-0.7 can 
      bear the evaluation of passing anticipated short-circuit current 1000A in the fusing time.


      ˣsize of outline and installation



      
      type and meaning of products




      3150A(4P),4000A and 5000A automatic transfer switches are equipped with four hoist rings. It is necessary to check whether hoist rings has 
      been tightened up to installation rail and make sure that the bearing capacity of rope cannot be less than 500kg before craning. Whats more, 
      it is obligatory to make certain switchs centre position of gravity lest some major accidents such as side-turn slide, etc happen because of the inaccurate 
      command of the center of gravity.



      [1]