      HZQ52-10/630A Dual power supply


      ŇťĄ˘HZQ53 three-step automatic transfer switch (20-5000) A

      1.Main circuit contact beside Power A

      2.on-off indicator of power

      3.option button

      4.trip button

      5.operating square shaft for manual switchover

      6.nameplate

      7.operating power terminal

      8.input circuit

      9.main circuit terminals beside the load

      10.main circuit terminals beside power B

      11.automatic switch

      12.Arc Extinguish Chamber


      śţŁŽHZQ52 three-step automatic transfer switch (20-5000) A
      1.Main circuit contact beside Power A

      2.on-off indicator of power

      3.operating square shaft for manual switchover

      4.nameplate

      5.operating power terminal

      6.input circuit

      7.main circuit terminals beside the load

      8.main circuit terminals beside power B

      9. Arc Extinguish Chamber

      10.automatic switch

      ČýĄ˘Features of ATS switch
      Reliable mechanical interlock: The unique eccentric selective structure makes
       sure one power supply to work and there is any possibility of two power sources
       connecting the load at the same time.

      Excellent arc extinction: all kinds of abnormal arc can be extinguished safely, 
      and the electric arc lasts for short time with less wear of the contact.

      Multiple-piece main arcing contact: increasing the contact terminalĄŻs area of surface in 
      contact and contact pressure. The superheat and welding wonĄŻt happen; the life of
       contact can be prolonged.

      Rapid switchover: it can switch rapidly between main power and standby pow
      er and the switching-time delay of ATS equipped with controller can be set by users.

      Simple structure and small size: stable running, low breakdown rate, convenient
       installation, usage and maintenance. Slow operation by rotating the handle while 
      maintaining in order to check and eliminate malfunction.

      HZQ5 ATS belongs to PC type. Its cubage is smaller than that of CB type, but its 
      ampere rating is more than that of PC type.

      Neutral pointĄŻs position: HZQ53 three-step switch can switch over in switch-on regime and stay momently in the neutral point so that it is convenient for users 
      to overhaul the load circuit(residence time shouldnĄŻt exceed several minutes.) HZQ52
       two-step type couldnĄŻt stay in the neutral point.

      Multifunctional controller: Liquid crystal display and digital dynamic supervisory control 
      display supply voltage and current, and control the transfer switch to finish switchover
       as required among main power, standby power and neutral point under the 
      circumstance of over-voltage, over low voltage,
       loss-of-voltage, and non-full-phase.


      ËÄĄ˘product model and meaning
      1Ą˘The model and meaning of products are as follows:



      1
      Ą˘HZQ52 is two-step automatic transfer switch. When receiving the change-over signal, the switch wonĄŻt stop in the middle splitting point and transfer rapidly 
      from one power to another power and its 
      ampere rating is only 20A-500A.

      HZQ53 is three-step automatic transfer switch. It can transfer instantly (or after a predetermined 
      time delay) from one power to anther power after receiving the change-over signal. It can also transfer to the middle splitting point disconnected with
       other power supplies. Its 
      ampere rating is 20A-5000A.

      2Ą˘HZQ5 series of switches is PC type.

      3Ą˘Other electric switches of other standards belong to special supply such as rated 
      operational current is 660v/690v, DC is 125v/250v; control voltage is 380v/400v/
      100v270v; DC is 125v/250v and so on. Users 

      4Ą˘should specify when ordering. 

      5Ą˘The switches below 500A should be generally connected in front and the switches 
      above 630A should be connected at back. The others belongs be special supply.


      Î奢Parameters of HZQ53 three-step transfer switch.


      ÁůŁŽThe parameters of HZQ52 two-step transfer switches.


      Notes: when the DC works, its structure of loop is almost as same as that of AC, 
      and only a small part is different. Please operate as the orders of AC operations.

      The weight in the chart is for reference only.

      Pole N contacts ĄŽcapacity of these products with 4000A and 5000A is relatively 
      2000A,2500A.

      Values of rated short time withstand current, operational current, and tipping 
      current are for reference only.


      Ćߥ˘Normal working condition and installation condition

      (1) When the DC works, its structure of loop is almost as same as that of DC, and 
      only a small part is different. Please operate as the orders of DC operations.

      (2)The outlines and sizes of these three different currents---80A/100A/125A are same as that of HZQ53 three-step transfer switches in the same standard.

         The outlines and sizes of these four different currents---160A/200A/225A /250A are same as that of HZQ53 three-step transfer switches in the same standard.

         The outlines and sizes of these three different currents---350A/400A/500A are same as that of the HZQ53 three-step transfer switches in the same standard.

      (1).Ambient temperature: -5ĄÍ - +40ĄÍ; the average value within 24h shall not exceed +35ĄÍ. (it can be extended 
      not higher than +55Ąć and not lower than -25Ąć according to usersĄŻ orders)

      (2). Altitude of installation place shall not exceed 2000m.

      (3). Atmospheric Condition: Relative humidity at +40ĄÍ shall not exceed 50%. Higher 
      humidity is permissible at lower temperature condition. When the highest monthly 
      average relative humidity is 90% in the humiddest month, the lowest monthly average 
      temperature of this month is +25
      ĄÍAnd the influence of dew on product surface due to
       temperature changes should be taken into consideration.

      (4). Pollution grade: complying with required grade iii of GB/t14048.1.

      (5).Installation type: electrical switchĄŻ installation should accord with required grade
       iii of
       GB/14048.1.

         Transfer controllerĄŻs installation should accord with required grade ii of GB/14048.1

      (6) Installation condition: electrical switches and transfer controller can be installed
       vertically or horizontally in specified control cabinet and distributor cabinet.

      (7) Protection grade: the shell protection of electric switches accord with the grade 20
       of GB4208 IP

         The shell protection of transfer controller accords with the grade 30 of GB4208.

      (8) Using sorts:

      main power circuit

      AC-33B
      occasional operation

      motor load or including motorŁŹresistive load mixed load with the load of 30% incandescent lamp

      auxiliary circuit and transfer control circuit

      AC-15
      DC-13

      control AC electromagnet load exceeds 75VŁŹcontrol DC electromagnet load 


      (9)control circuit:

      Rated voltage of control circuit is 220V/250V/50HZ. The voltage of control circuit should 
      accord with the working voltage of transfer controller. 
      Its working range: 85% Uc¨QUs¨Q110%Uc.

      The transfer controller will give conversion instructions when the following happens:

      A disconnection of any phase power or loss of voltage.

      B low voltage: voltage from 180V-230v can be set in a random manner

      C over voltage: voltage from 220V-250v can be set in a random manner

      When delivered, the rated working current is 220V, and its transfer voltage is low voltage 
      180V and over voltage is 250V 

      (10)auxiliary circuit:

      The auxiliary contact of auxiliary circuit, whose structure is separable, is 4 NO and 4 NC.Ł¨The rated value of the auxiliary is shown in table 5ŁŠ

      Ith A

      rated insulation voltage V

      rated working current

      10

      400

      AC400

      DC200

      3

      0.2

      abnormal disconnection of auxiliary breaking capacity is shown in table 6

      Using sorts

      connection

      breaking

      operation frequency and numbers of cycling

      1/le

      U/ue

      Cos and t0.95

      1/le

      U/ue

      Cos and t0.95

      numbers of cycling

      operation frequency 

      electrical running time S

      AC-15

      10

      1.1

      0.3

      10

      1.1

      0.3

      10

      2

      ĄÝ 0.05

      DC-13

      1.1

      1.1

      6pe

      1.1

      1.1

      6pe

      notesŁşthe upper limit T0.95ĄÖ6Pe¨Q300Ms.the electrical running time of DCĄŞĄŞ13 is T0.95 at least when T0.95 ¨R 0.05S.

      Coordination of auxiliary contact and SCPD.

      Series connection of auxiliary contact and fuse in inductive testing circuit whose rated 
      working current is 1.1 times and power factor is between 0.5-0.7 can bear the evaluation of passing anticipated short-circuit current 1000A in the fusing time.


      °ËŁŽsize of outline and installation


      žĹĄ˘type and meaning of products


      1Ą˘HZQ52 is two-step automatic transfer switch. When receiving the change-over signal, the switch wonĄŻt stop in the middle splitting point and transfer rapidly 
      from one power to another power and its 
      ampere rating is only 20A-500A.

      HZQ53 is three-step automatic transfer switch. It can transfer instantly (or after a predetermined 
      time delay) from one power to anther power after receiving the change-over signal. It can also transfer to the middle splitting point disconnected with
       other power supplies. Its 
      ampere rating is 20A-5000A.

      2Ą˘HZQ5 series of switches is PC type.

      3Ą˘Other electric switches of other standards belong to special supply such as rated 
      operational current is 660v/690v, DC is 125v/250v; control voltage is 380v/400v/
      100v270v; DC is 125v/250v and so on. Users 

      4Ą˘should specify when ordering. 

      5Ą˘The switches below 500A should be generally connected in front and the switches 
      above 630A should be connected at back. The others belongs be special supply.


      Î奢Parameters of HZQ53 three-step transfer switch.


      ÁůŁŽThe parameters of HZQ52 two-step transfer switches
      .

      Notes: when the DC works, its structure of loop is almost as same as that of AC, 
      and only a small part is different. Please operate as the orders of AC operations.

      The weight in the chart is for reference only.

      Pole N contacts ĄŽcapacity of these products with 4000A and 5000A is relatively 
      2000A,2500A.

      Values of rated short time withstand current, operational current, and tipping 
      current are for reference only.


      Ćߥ˘Normal working condition and installation condition

      (1) When the DC works, its structure of loop is almost as same as that of DC, and 
      only a small part is different. Please operate as the orders of DC operations.

      (2)The outlines and sizes of these three different currents---80A/100A/125A are same as that of HZQ53 three-step transfer switches in the same standard.

         The outlines and sizes of these four different currents---160A/200A/225A /250A are same as that of HZQ53 three-step transfer switches in the same standard.

         The outlines and sizes of these three different currents---350A/400A/500A are same as that of the HZQ53 three-step transfer switches in the same standard.

      (1).Ambient temperature: -5ĄÍ - +40ĄÍ; the average value within 24h shall not exceed +35ĄÍ. (it can be extended 
      not higher than +55Ąć and not lower than -25Ąć according to usersĄŻ orders)

      (2). Altitude of installation place shall not exceed 2000m.

      (3). Atmospheric Condition: Relative humidity at +40ĄÍ shall not exceed 50%. Higher 
      humidity is permissible at lower temperature condition. When the highest monthly 
      average relative humidity is 90% in the humiddest month, the lowest monthly average 
      temperature of this month is +25
      ĄÍAnd the influence of dew on product surface due to
       temperature changes should be taken into consideration.

      (4). Pollution grade: complying with required grade iii of GB/t14048.1.

      (5).Installation type: electrical switchĄŻ installation should accord with required grade
       iii of
       GB/14048.1.

         Transfer controllerĄŻs installation should accord with required grade ii of GB/14048.1

      (6) Installation condition: electrical switches and transfer controller can be installed
       vertically or horizontally in specified control cabinet and distributor cabinet.

      (7) Protection grade: the shell protection of electric switches accord with the grade 20
       of GB4208 IP

         The shell protection of transfer controller accords with the grade 30 of GB4208.

      (8) Using sorts:

      main power circuit

      AC-33B
      occasional operation

      motor load or including motorŁŹresistive load mixed load with the load of 30% incandescent lamp

      auxiliary circuit and transfer control circuit

      AC-15
      DC-13

      control AC electromagnet load exceeds 75VŁŹcontrol DC electromagnet load 


      (9)control circuit:

      Rated voltage of control circuit is 220V/250V/50HZ. The voltage of control circuit should 
      accord with the working voltage of transfer controller. 
      Its working range: 85% Uc¨QUs¨Q110%Uc.

      The transfer controller will give conversion instructions when the following happens:

      A disconnection of any phase power or loss of voltage.

      B low voltage: voltage from 180V-230v can be set in a random manner

      C over voltage: voltage from 220V-250v can be set in a random manner

      When delivered, the rated working current is 220V, and its transfer voltage is low voltage 
      180V and over voltage is 250V 

      (10)auxiliary circuit:

      The auxiliary contact of auxiliary circuit, whose structure is separable, is 4 NO and 4 NC.

      Coordination of auxiliary contact and SCPD.

      Series connection of auxiliary contact and fuse in inductive testing circuit whose rated 
      working current is 1.1 times and power factor is between 0.5-0.7 can bear the evaluation of passing anticipated short-circuit current 1000A in the fusing time.


      °ËŁŽsize of outline and installation


      žĹĄ˘type and meaning of products

      [1]